Perkins

Home / Perkins

DG SETS POWERED BY PERKINS

  • Heavy duty Perkins diesel engine
  • Four stroke, water cooled, turbocharged
  • Direct injection fuel system
  • Mechanical /Electronic Governor System
  • 12/24 V D.C. starter and charge alternator
  • Replaceable fuel filter, oil filter and dry element air filter
  • Cooling radiator and fan
  • Starter battery (with lead acid) including Rack and Cables
  • Flexible fuel connection hoses and manual oil sump drain valve
  • Industrial capacity exhaust silencer and bellows
  • Brushless, single bearing system
  • flexible disc, 4 poles
  • Insulation class H
  • Standard degree of protection IP21 (*IP22/IP23 is available.
  • Self-exciting and self-regulating
  • Impregnation with tropicalized epoxy varnish
  • Solid state Automatic Voltage Regulator
  • Stator winding with 2/3 pitch for improved Harmonics
  • The complete gen-set is mounted as whole on a Heavy-duty fabricated, steel base frame
  • Anti-vibration pads are fixed between the engine/ Alternator feet and the base frame
  • Base frame design incorporates an integral Fuel Tank (Up to 750 kVA)
  • The generating set can be lifted or carefully Pushed / pulled by the base frame
  • Dial type fuel gauge and drain plug on the fuel Tank
  • Forklift pockets within base frame (up to 500kVA)
  • All canopy parts are designed with modular Principles
  • Without welding assembly
  • Doors on each side
  • All metal canopy parts are painted by electrostatic polyester powder paint
  • Exhaust silencer is protected against environment influences
  • Thermally insulated engine exhaust system
  • Emergency stop push button is installed outside of the canopy
  • Easy lifting ,moving & easy maintenance and operation
  • Operation manuals and circuit diagram and documents

3 PHASE, 415 V, 50 HZ, 1500 RPM, RATING AT 0.8 PF

GENSET MODEL CUMMINS ENGINE LEROYS SOMER ALTERNATOR PRIME POWER STAND BY POWER
KVA KW KVA KW
EP 9 403A-11G1 TAL 040 B 9 7 10 8
EP13 403A-15G1 TAL 040 D 13 10 15 11
EP15 403A-15G2 TAL 040 D 15 12 16.5 13.2
EP20 404A-22G1 TAL 040 F 20 16 22 18
EP30 1103A-33G TAL 042 C 30 24 33 26
EP45 1103A-33TG1 TAL 042 F 45 36 50 40
EP60 1103A-33TG2 TAL 042 H 60 48 66 53
EP80 1104A-44TG2 TAL 044 B 80 64 88 70
EP100 1104C-44TAG2 TAL 044 D 101 81 112 90
EPC 250 QSL9-G3 TAL 046D 250 200 275 220
EP130 1106A-70TG1 TAL 044 H 135 108 150 120
EP150 1106A70TAG2 TAL 044 J 150 120 165 132
EP180 1106A70TAG3 TAL 046 A 180 144 200 160
EP200 1106A70TAG4 TAL 046 B 200 160 220 176
EP250 1206A-E 70 TTAG3 TAL 046 D 250 200 275 220
EP300 1506A-E88TAG5 TAL 046 F 300 240 330 264
EP350 2206A-E13TAG2 TAL 046 H 350 280 400 320
EP400 2206A-E13TAG3 TAL 047A 400 320 450 360
EP450 2506A-E15TAG1 TAL 047C 455 364 500 400
EP500 2506A-E15TAG2 TAL 047C 500 400 550 440
EP600 2806A-E18TAG1A TAL 047 E 600 480 660 528
EP650 2806A-E18TAG2 TAL 047F 650 520 700 560
EP750 4006-23TAG2A TAL 049 C 750 600 825 660
EP800 4006-23TAG3A TAL 049 C 800 640 900 720
EP1000 4008TAG2A TAL 049 E 1022 818 1125 900
EP1250 4012-46TWG2A LSA 50.2 M6 1250 1000 1385 1000
EP1360 4012-46TAG1A LSA 50.2 L7 1360 1100 1500 1200
EP1500 4012-46TAG2A LSA 50.2L8 1500 1200 1650 1320
EP1700 4012-46TAG2A LSA 50.3 S5 1710 1350 1875 1500
EP1850 4016TAG1A LSA 50.3 S5 1850 1480 2000 1600
EP2000 4016TAG2A LSA 50.3 S6 2000 1600 2250 1800
EP2250 4016-61TRG3 LSA 52.3 S7 2250 1800 2500 2000

Standard Control Panel: 9 KVA up to 650 KVA – Deep Sea 6010 750 KVA up to 2500 KVA – Deep Sea 7320 * Customized Solutions are also available.

Rating Definitions: Prime: These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of Commercially purchased power. 10% overload power is available for 1 hour in 12 hours continuous operation.

Standby: These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a Utility power failure. No overload is permitted on these ratings.Note: All ratings @ Factory Standard Conditions.